MBT Rebar Coupler Price List Guide | Leo Industries
MBT Rebar Coupler Price List Guide
If you are searching for an MBT rebar coupler price list, the best approach is to build a clear specification-based schedule that matches your project design and approval requirements. MBT (Mechanical Bolted) couplers use shear-head bolts to clamp onto reinforcement bars without threading, making them a preferred solution for fast-track works, retrofit jobs, and sites with limited equipment. Because requirements vary across bar sizes, grades, coatings, and test standards, quotations are typically prepared from a BOQ that lists each diameter, type, and compliance need. This page helps you create that BOQ correctly so you can receive an accurate, comparable quotation for your project.
Working Principle & Process Flow
An MBT rebar coupler consists of a high-strength sleeve and a set of shear-head bolts. Two bar ends are inserted to the center stop, then bolts are tightened using a standard impact wrench. As tightening continues, the bolts grip the bar and achieve a specified clamping force. When the correct torque is reached, each bolt head shears off, providing a clear visual confirmation of proper installation. This simple workflow supports consistent site quality control and helps reduce dependence on specialized threading machines or bar preparation tools.
Applications & Benefits
Applications
Fast-track RCC projects where rapid rebar splicing is required
Retrofit and strengthening works with limited bar projection length
Rebar cage closures and congested reinforcement zones
Repair splices in existing structures and extensions of slabs or beams
Sites where threading, swaging, or bar-end preparation is not feasible
Benefits
No threading required, enabling simpler site execution
Shear-off bolt heads provide quick installation verification
Helps reduce labor complexity with standard tooling
Supports dependable load transfer when specified and installed correctly
Key Features
Shear-head bolt system for consistent tightening and inspection
High-strength sleeve construction for durable site handling
Internal grip design engineered to clamp securely on rebar ribs
Options available for standard, reducer, and positional requirements
Suitable for projects prioritizing speed and simplified execution
How to Prepare a Coupler BOQ for Accurate Quotations
Instead of relying on a generic price list, prepare a project BOQ that suppliers can quote against consistently. Start by listing each bar diameter and the quantity of splices needed. Next, specify the coupler type required, such as standard, reducer (for different bar diameters), or positional variants where access is restricted. Mention the bar grade and any project-specific requirements for corrosion protection, such as coating preferences for coastal or aggressive environments. Finally, include the acceptance criteria required by your consultant, such as performance class, test reports, and inspection or traceability documentation. This method keeps comparisons fair and helps avoid scope gaps during procurement.
Maintenance & Safety Tips
ChecklistLeoindustries
Pre-Installation
Confirm bar diameter, grade, and splice type match the approved drawings
Ensure rebar ends are clean and free from mud, oil, or loose rust flakes
Use the correct tool and socket size recommended for the coupler bolts
Installation Practices
Insert bars fully until they meet the internal center stop
Tighten bolts in the recommended sequence for uniform clamping
Verify all bolt heads have sheared off for clear completion evidence
FAQs — MBT Rebar Coupler Price List
Q1
Can you share an MBT rebar coupler price list?
Coupler requirements change by bar diameter, type, grade, coating, and testing needs, so quotations are best prepared from a BOQ. Share your sizes and quantities to receive a specification-matched quotation.
Q2
What details should be included in the BOQ for a proper quotation?
Include bar diameters, splice quantities, coupler type (standard or reducer), bar grade, coating requirements, and the acceptance criteria needed by your consultant such as test reports and traceability.
Q3
Do MBT couplers require threading or special bar-end preparation?
No. MBT couplers clamp onto the rebar using shear bolts, so threading is not required. Proper cleaning and correct insertion depth are important for consistent installation.
Q4
How is installation checked on site?
The shear-head bolt design provides a clear visual check. When tightened correctly, bolt heads shear off, indicating that the required torque has been achieved.
Q5
Can MBT couplers be used for bars of different diameters?
Yes. Reducer couplers are used to connect different bar sizes. Specify both diameters in your BOQ so the correct reducer configuration can be offered.